Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
São Paulo med. j ; 139(3): 218-225, May-June 2021. tab, graf
Article in English | LILACS | ID: biblio-1252250

ABSTRACT

ABSTRACT BACKGROUND: In July 2012, the Japan Gastroenterological Endoscopy Society updated their guidelines for gastroenterological endoscopy in patients receiving antithrombotic therapy. Colonoscopic polypectomy procedures are associated with a high risk of bleeding. OBJECTIVES: The present study evaluated the safety of colonoscopic polypectomy procedures in terms of bleeding, among patients receiving antithrombotic therapy. DESIGN AND SETTING: Prospective observational study conducted in a tertiary-level public cardiovascular hospital in Istanbul, Turkey. METHODS: Colonoscopic polypectomies carried out in a single endoscopy unit between July 2018 and July 2019 were evaluated prospectively. The patients' data, including age, gender, comorbidities, whether antithrombotic drug use was ceased or whether patients were switched to bridging therapy, polyp size, polyp type, polyp location, histopathology, resection methods (hot snare, cold snare or forceps) and complications relating to the procedures were recorded. RESULTS: The study was completed with 94 patients who underwent a total of 167 polypectomy procedures. As per the advice of the physicians who prescribed antithrombotic medications, 108 polypectomy procedures were performed on 60 patients without discontinuing medication and 59 polypectomy procedures were performed on 34 patients after discontinuing medication. The age, gender distribution and rate of bleeding did not differ significantly between the patients whose medication was discontinued and those whose medication was continued (P > 0.05). CONCLUSION: This study found that the colonoscopic polypectomy procedure without discontinuation of antithrombotic medication did not increase the risk of bleeding. This procedure can be safely performed by experienced endoscopists in patients with an international normalized ratio (INR) below 2.5.


Subject(s)
Humans , Colonic Polyps/surgery , Fibrinolytic Agents/adverse effects , Turkey , Retrospective Studies , Colonoscopy , Postoperative Hemorrhage/chemically induced , Postoperative Hemorrhage/epidemiology
2.
Clinics ; 67(9): 1035-1038, Sept. 2012. tab
Article in English | LILACS | ID: lil-649382

ABSTRACT

OBJECTIVE: This prospective study was conducted to compare the clinical outcomes of a 6-row 3-D linear cutter with the standard 4-row linear cutter in patients who underwent elective gastrointestinal surgery anastomosis. METHOD: Patients who underwent elective open gastrointestinal surgery that included stapled anastomosis using a linear cutter (Proximate®, Ethicon Endo-Surgery, Cincinnati, OH) between January 2011 and May 2011 were included in the study. The patients were randomly assigned to two groups according to the linear cutter that was used in the surgery: the standard 4-row cutter (the S group) or the new 6-row cutter (the N group). The groups were compared based on the patient demographic data, the laboratory parameters, the preoperative diagnosis, the surgery performed, the operation time, intra-or postoperative complications, the time to oral tolerance and the length of the hospital stay. RESULTS: The S group included 11 male and nine female patients with a mean age of 65 ± 12 (35-84) years, while the N group included 13 male and eight female patients with a mean age of 62 ±11 (46-79) years (p =0.448, p = 0.443, respectively). Anastomotic line bleeding was observed in eight (40%) patients in the S group and in one (4.7%) patient in the N group (p = 0.006). Dehiscence of the anastomosis line was observed in two (10%) patients in the S group and none in the N group (p =0.131). Anastomotic leakage developed in three (15%) patients in the S group and in one (4.7%) patient in the N group (p = 0.269). The mean hospital stay was 12.65 ± 6.1 days in theS group and 9.52 ± 2.9 days in the N group (p = 0.043). CONCLUSION: The 6-row 3-D linear cutter is a safe and easily applied instrument that can be used to create anastomoses in gastrointestinal surgery. The new stapler provides some usage benefits and is also superior to the standard linear cutter with regard to anastomotic line bleeding.


Subject(s)
Adult , Aged , Female , Humans , Male , Middle Aged , Digestive System Surgical Procedures/instrumentation , Surgical Staplers , Anastomosis, Surgical/instrumentation , Blood Loss, Surgical , Chi-Square Distribution , Digestive System Surgical Procedures/methods , Length of Stay , Perioperative Period , Postoperative Hemorrhage , Prospective Studies , Reproducibility of Results , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL